NAVIGATION
- Inert Gas GLovebox
- Gas purification systems
- Glovebox Industry applications&Solutions
- Feedthroughs & Viewports
- Glovebox Accessories
- Plasma/UV-Zone Cleaners
- Ultrasonics/Water Circulator
- Film Coating
- Electronic Packages
- Battery R&D Equipment
- R2R Flexible Electronics Printing
LATEST NEWS
- Made in Space – 1st ISS 3D Printer
- M-Braun Glovebox System Operation Procedur
- Stainless steel glove box
- NREL test helps make moisture barriers bet
- Organic/inorganic sulfur may be key for sa
- Grant supports development of next-generat
CONTACT US
- Add: RM 1802B-A6 Fortress Tower 250 Kings RD North Point HongKong
- Tel: +86 010 8499 8901
- Fax: +86 010 8499 8901
- Email: adahan@foxmail.com
ONLINE STORE
AMI 2001 series Trace Oxygen Analyzer
- Product description: AMI 2001 series Trace Oxygen Analyzer,Glovebox
Product introduction
Model |
Description |
Content |
MODEL 2001RS
|
Picture |
|
Overview |
- Display reads oxygen from 0.05ppm up to 25.0% with no range changes - Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution - Analog output 4-20mA, isolated. - Complete sample system built into AMI’s patented cell block. - Very rapid response time from air to low ppm levels. - Easily replaceable sensor, no tools required. - T-2 sensor resistant up to 10ppm H2S. - Simple, versatile installation. - Operates off 117VAC with very low power consumption - Analog output can be easily calibrated to an external device. - 2 independent, fully adjustable alarm settings with relay contacts. - Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off. - Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc. - USB connectivity to a PC: Allows complete access to the internal functions and settings. - ModBus Industry standard protocol over RS485. - Oxygen Sensor life indication. - Calibration history. |
|
Feature |
- 10 user selectable output ranges - 3 1/2 digit LCD - 2 fully adjustable oxygen concentration alarms - Alarm hold off/Bypass - RFI protected - 4-20mA. isolated analog output - Analog output calibration synchronizes the analog output with an external monitoring system - Data logger - Fully programmable alarm delays - USB port for configuration and access to advanced features - Calibration history and sensor usage logging - Power brownout and power failure logging - Modbus using Bidirectional RS485 for industry-standard communications - Low minimum detection limit 0.05ppm - Excellent repeatability - Extended operating temperature range - Fast upscale/downscale response times - Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings. - Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools. - Unaffected by changes in flow rate from 0.1 to 2.0 SCFH - Panel mount - Compact size - 2 year warranty for analyzer, parts and labor - 6 month sensor warranty, life expectancy 1-2 years - Requires optional AMI User Interface software |
|
Specifications |
- 2001R Series Standard ranges: - 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25% - Sensitivity: 0.5% of full scale - Repeatability: +/- 1% of full scale at constant temperature - Operating temperature: 41°F to 113°F. - Maximum inlet pressure: 20psig - Humidity: < 85%, non-condensing - Operational conditions: Pollution degree 2, Installation category I I. - Drift: +/- 1% of full scale in 4 weeks at constant temperature - Expected cell life: 9 months to 2 years. - Response times (dependent on sensor): - 90% of full scale in less than: - 0 – 10 ppm 25 sec - 0 – 100 ppm 10 sec - 0 – 1000 ppm 10 sec - Outputs: 4-20mA isolated. - Alarm contacts: 230/117VAC @ 5A, or 28VDC @ 5A, resistive - Datalogger: Logs data for 15 days @ 1 minute intervals; 30 days @ 2 minute intervals, etc. Represents the output range selected: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and 25%. Overange capability up to ten times the range selected. - Power requirements: 90-240VAC <10W. - Absolute Maximum Power voltage 264VAC 60Hz. - ¼” Stainless Steel compression fittings for sample, span gas and exhaust. - Overall dimensions: 9” w x 5” h x 7” d - Weight 10 lbs |
|
MODEL 2001RSP
|
Picture |
|
Overview |
- Display reads oxygen from 0.05ppm up to 25.0% with no range changes - Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution - Analog output 4-20mA, isolated. - Complete sample system built into AMI’s patented cell block. - Very rapid response time from air to low ppm levels. - Easily replaceable sensor, no tools required. - T-2 sensor resistant up to 10ppm H2S. - Simple, versatile installation. - Operates off 117VAC with very low power consumption - Analog output can be easily calibrated to an external device. - 2 independent, fully adjustable alarm settings with relay contacts. - Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off. - Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc. - USB connectivity to a PC: Allows complete access to the internal functions and settings. - ModBus Industry standard protocol over RS485. - Oxygen Sensor life indication. - Calibration history. |
|
Feature |
- 10 user selectable output ranges - 3 1/2 digit LCD - 2 fully adjustable oxygen concentration alarms - Alarm hold off/Bypass - RFI protected - 4-20mA. isolated analog output - Analog output calibration synchronizes the analog output with an external monitoring system - Data logger - Fully programmable alarm delays - USB port for configuration and access to advanced features - Calibration history and sensor usage logging - Power brownout and power failure logging - Modbus using Bidirectional RS485 for industry-standard communications - Low minimum detection limit 0.05ppm - Excellent repeatability - Extended operating temperature range - Fast upscale/downscale response times - Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings. - Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools. - Unaffected by changes in flow rate from 0.1 to 2.0 SCFH - Panel mount - Compact size - 2 year warranty for analyzer, parts and labor - 6 month sensor warranty, life expectancy 1-2 years - Requires optional AMI User Interface software |
|
Specifications |
- 2001R Series Standard ranges: - 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25% - Sensitivity: 0.5% of full scale - Repeatability: +/- 1% of full scale at constant temperature - Operating temperature: 41°F to 113°F. - Maximum inlet pressure: 20psig - Humidity: < 85%, non-condensing - Operational conditions: Pollution degree 2, Installation category I I. - Drift: +/- 1% of full scale in 4 weeks at constant temperature - Expected cell life: 9 months to 2 years. - Response times (dependent on sensor): - 90% of full scale in less than: - 0 – 10 ppm 25 sec - 0 – 100 ppm 10 sec - 0 – 1000 ppm 10 sec - Outputs: 4-20mA isolated. - Alarm contacts: 230/117VAC @ 5A, or 28VDC @ 5A, resistive - Datalogger: Logs data for 15 days @ 1 minute intervals; 30 days @ 2 minute intervals, etc. Represents the output range selected: 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-.500%, 0-1%, 0-5%, 0-10% and 25%. Overange capability up to ten times the range selected. - Power requirements: 90-240VAC <10W. - Absolute Maximum Power voltage 264VAC 60Hz. - ¼” Stainless Steel compression fittings for sample, span gas and exhaust. - Overall dimensions: 9” w x 5” h x 7” d - Weight 10 lbs |
|
MODEL 2001RSM
|
Picture |
|
Overview |
- Display reads oxygen from 0.05ppm up to 25.0% with no range changes - Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution - Analog output 4-20mA, isolated. - Complete sample system built into AMI’s patented cell block. - Scans through up to five sample inputs, or may be set to dwell on any of them. - Very rapid response time from air to low ppm levels. - Easily replaceable sensor, no tools required. - T-2 sensor resistant up to 10ppm H2S. - Simple, versatile installation. - Operates off 117VAC with very low power consumption - Analog output can be easily calibrated to an external device. - 2 independent, fully adjustable alarm settings with relay contacts. - Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off. - Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc. - USB connectivity to a PC: Allows complete access to the internal functions and settings. - ModBus Industry standard protocol over RS485. - Oxygen Sensor life indication. |
|
Feature |
- Built-in sample channel sequencer with up to 5 input channels. - 10 user selectable output ranges - 3 1/2 digit LCD - 2 fully adjustable oxygen concentration alarms - Alarm hold off/Bypass - RFI protected - 4-20mA. isolated analog output - Analog output calibration synchronizes the analog output with an external monitoring system - Data logger - USB port for configuration and access to advanced features - Calibration history and sensor usage logging - Power brownout and power failure logging - Modbus using Bidirectional RS485 for industry-standard communications - Low minimum detection limit 0.05ppm - Excellent repeatability - Extended operating temperature range - Fast upscale/downscale response times - Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings. - Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools. - Unaffected by changes in flow rate from 0.1 to 2.0 SCFH - Panel mount - Compact size - 2 year warranty for analyzer, parts and labor - 6 month sensor warranty, life expectancy 1-2 years - Requires optional AMI User Interface software |
|
Specifications |
- 2001R Series Standard ranges: - 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25% - Sensitivity: 0.5% of full scale - Repeatability: +/- 1% of full scale at constant temperature - Operating temperature: 41°F to 113°F. - Maximum inlet pressure: 20psig - Humidity: < 85%, non-condensing - Operational conditions: Pollution degree 2, Installation category I I. - Drift: +/- 1% of full scale in 4 weeks at constant temperature - Expected cell life: 9 months to 2 years. - Response times (dependent on sensor): - 90% of full scale in less than: - 0 – 10 ppm 25 sec - 0 – 100 ppm 10 sec - 0 – 1000 ppm 10 sec - Outputs: 4-20mA isolated. - Alarm contacts: 230/117VAC @ 5A, or 28VDC @ 5A, resistive - Power requirements: 90-240VAC <10W. - Absolute Maximum Power voltage 264VAC 60Hz. - Overall dimensions: 9” w x 5” h x 7” d - Weight 10 lbs |
|
MODEL 2001RSPM
|
Picture |
|
Overview |
- Display reads oxygen from 0.05ppm up to 25.0% with no range changes - Analog output and alarms can be configured to operate over any of ten ranges from 0-10ppm to 0-25% for best resolution - Analog output 4-20mA, isolated. - Complete sample system built into AMI’s patented cell block. - Scans through up to five sample inputs, or may be set to dwell on any of them. - Very rapid response time from air to low ppm levels. - Easily replaceable sensor, no tools required. - T-2 sensor resistant up to 10ppm H2S. - Simple, versatile installation. - Operates off 117VAC with very low power consumption - Analog output can be easily calibrated to an external device. - 2 independent, fully adjustable alarm settings with relay contacts. - Complete alarm logic programming: latching or non-latching, open or close on alarm, high alarm or low alarm, alarm-on delays and alarm hold-off. - Integral data logger: Logs data for 15 days @ 1min intervals and 30 days @ 2min. intervals, etc. - USB connectivity to a PC: Allows complete access to the internal functions and settings. - ModBus Industry standard protocol over RS485. - Oxygen Sensor life indication. |
|
Feature |
- Built-in sample channel sequencer with up to 5 input channels. - 10 user selectable output ranges - 3 1/2 digit LCD - 2 fully adjustable oxygen concentration alarms - Alarm hold off/Bypass - RFI protected - 4-20mA. isolated analog output - Analog output calibration synchronizes the analog output with an external monitoring system - Data logger - USB port for configuration and access to advanced features - Calibration history and sensor usage logging - Power brownout and power failure logging - Modbus using Bidirectional RS485 for industry-standard communications - Low minimum detection limit 0.05ppm - Excellent repeatability - Extended operating temperature range - Fast upscale/downscale response times - Patented Cellblock Technology: Allows for all components such as flow control valve, flow meter, Sample, span and seal-off solenoid valves and compression fittings to be an integral part of the cellblocks, eliminating long lengths of tubing and fittings. - Benefits of this design include compact size, faster response times and front panel sensor access without the need for tools. - Unaffected by changes in flow rate from 0.1 to 2.0 SCFH - Panel mount - Compact size - 2 year warranty for analyzer, parts and labor - 6 month sensor warranty, life expectancy 1-2 years - Requires optional AMI User Interface software |
|
Specifications |
- 2001R Series Standard ranges: - 0 – 10 ppm, 0 – 50ppm, 0 –100 ppm, 0 – 500 ppm, 0 – 1000ppm, 0 – 5000 ppm, 0 – 1%, 0 – 5%, 0 – 10%, 0 –25% - Sensitivity: 0.5% of full scale - Repeatability: +/- 1% of full scale at constant temperature - Operating temperature: 41°F to 113°F. - Maximum inlet pressure: 20psig - Humidity: < 85%, non-condensing - Operational conditions: Pollution degree 2, Installation category I I. - Drift: +/- 1% of full scale in 4 weeks at constant temperature - Expected cell life: 9 months to 2 years. |