Single-Side lab2000(2400×750)
- lab2000(2400×750)
- H2O<1PPM,O2<1PPM
- Main Accessories: Edward RV12 vacuum pump, GE water oxygen Analyzer
- Last time:2016-8-25 13:09:30
- Product description: Product description: Product description: Glove box is a kind of equipment to provide no water and no oxygen environment. The equipment mainly includes the box of the device, the transfer chamber, cyc
Product introduction
Specification:
Picture
|
||||||
Structure |
Integrated structure (Purification System integrated under the box) |
|||||
Power Supply |
110 - 220V AC, 50/60Hz, Single-phase |
|||||
Glove box Box |
Box Material: 304 Stainless Steel (Type 304), thickness 3mm 2400mm(L) x 750mm(W) x 900mm(H) 94.49" x 29.5" x 35.4" Box Support height: 900mm(35.43" )
|
|||||
Tray |
Standard Layout
|
Two layers in box. |
||||
Option/Add: tool boxes or other
|
Various tool boxes, can be placed according to user needs. |
|||||
Front window |
Tilt design operating window, removable safety toughened glass front window, 8mm thickness,Wear resistance, corrosion resistance, good light transmission, sealing ring using 3/8 inch thick OMEGA sealing ring. |
|||||
Option: Window Open |
The front window can be designed to open instead of fix, in order to put in a variety of instruments (custom function).
|
|||||
Environment of Box inside |
H2O <1 ppm (20°C/68 ℉, 1 atm) |
|||||
Antechamber |
Control way: manual |
|||||
Option/add auto control way
|
It will automatically control the antechamber by time setting and the number of times for gas exhaust and filling. |
|||||
Option/Add: heating mode |
Max temperature:200℃/ 392℉ |
|||||
Working gas and regeneration gas |
Working gas: 99.999% high pure N2, Ar, He and other inert gas |
|||||
Gas purification system |
Single pure column: |
|||||
Option: dual columns purification system |
Why choose duel pure column? 1、The Pure column need to be regenerated after saturated by absorbing the oxygen and moisture. The regeneration time is 16hours. If there is no reserved column, it may stop working. (we recommend dual column purification system to factory or other unit which need glove box working Continuously); 2、The pure capacity of dual pure columns is two times as much as single column |
|||||
Pressure control system |
Box pressure can be auto controlled by PLC touch screen |
|||||
Filter system |
The ends of inlet and outlet both are provided with filter |
|||||
Closed circulating fan |
High speed frequency conversion fan, flow 0-100m3/h, microprocessor control, Stainless steel device for pressure testing. |
|||||
Control system |
SIEMENS colors touch screen (6 inches), PLC control system, Bilingual in Chinese and English can be switched |
|||||
Moisture analyzer: US GE brand, 0~1000ppm touch screen display, precision 0.1ppm |
||||||
Oxygen analyzer: US GE brand, 0~1000ppm touch screen display, precision 0.1ppm |
||||||
Britain Brand EDWARDS, pumping speed 8.4-12m3/h, Model: RV12 |
||||||
Brand: US |
||||||
illumination system |
Equipped with Fluorescent lamp. Brand: PHILIPS |
|||||
Solvent removal system |
Efficient adsorption of activated carbon, can effectively remove trace organic solvents; |
|||||
Spare KF40 standard joint |
Special design to KF40 Joint, you can lead the water into the box |
|||||
Can be connected to other devices (low temperature refrigerator, film coating machine, microscope, solvent purification system, low temperature cold trap, heating furnace, etc.) |
low temperature refrigerator |
|
||||
microscope |
|
|||||
Solvent Purification System |
|
|||||
Coating machine |
Inside connection(one door of Coating machine is inside of glove box) |
|||||
Equipment size and room requirements |
Overall size |
3050mm(L) x 1000mm(W) x 1950mm(H) 120.08" x39.37" x 76.77"
|
||||
Room size |
3400mm(L) x 1500mm(W) x 2000mm(H) 133.86" x59" x 78.74"
|
|||||
Wooden Package size and weight |
3385mm(L) x 1145mm(W) x 2300mm(H) 133.27" x 45" x 91" (9.0M3)
|
|||||
1020 kg (2197 lbs)
|
||||||
Notice |
When the gas is circulating, must ensure that the piping of the circulation system is clear and cannot be blocked (if the color of the filter is changed from white to black, the filter should be replaced timely). |